• Automatically Adjustable Air Volume with Actuator Vav Damper
  • Automatically Adjustable Air Volume with Actuator Vav Damper
  • Automatically Adjustable Air Volume with Actuator Vav Damper
  • Automatically Adjustable Air Volume with Actuator Vav Damper
  • Automatically Adjustable Air Volume with Actuator Vav Damper
  • Automatically Adjustable Air Volume with Actuator Vav Damper

Automatically Adjustable Air Volume with Actuator Vav Damper

Media: Gas
Driving Mode: Electric
Connection Form: Flange
Structure: Centre Sealing
Seal Form: Force Sealed
Valve Stem: Normal
Samples:
US$ 358/Piece 1 Piece(Min.Order)
| Request Sample
Customization:

360° Virtual Tour

Diamond Member Since 2019

Suppliers with verified business licenses

Guangdong, China
to see all verified strength labels (15)

Basic Info.

Work Pressure
MID-Pressure (2.5MPa< Pn <6.4MPa)
Working Temperature
Normal Temperature (-40°C<T<120°C)
Application
Industrial Usage, Household Usage, Exhaust Gas System
Material of Seal Surface
Plastic
Valve Body
Mould
Trademark
Xicheng
Origin
China
Production Capacity
Customer Use

Product Description

Product Description
The VAV damper contains an averaging airflow measurement probe, airflow controller and actuator. Airflow is controlled based on actual flow measurement by changing the damper blade position.
VAV is the abbreviation of Variable Air Volume. In the air conditioning system, in order to cope with the change of the terminal load, when the flow of the cooling/heating medium remains unchanged, the air volume needs to be adjusted to adjust the delivery of
cold/heat to meet the changing demand.

 
For the VAV system, the control methods can be generally divided into three types:

1.Constant and static pressure control: Its working principle is that in the system, the VAV BOX controller adjusts the air volume at the end to meet the load requirements according to the indoor load changes. The change of air output causes the change of static pressure in the system pipeline. The static pressure sensor measures the change of static pressure and transmits it to the fan inverter DDC. The inverter DDC controls the motor speed of the air conditioner according to the static pressure change signal,adjusts the total air output, and maintains The static pressure of the supply air piping system is constant.
 
2.Variable static pressure control: its working principle is that the system will try to keep the VAVBOX in a fully open state (85-100%) under the condition that the system meets the requirements of indoor load changes to keep the system static pressure to the bottom.
 
3.Total air volume control: Its working principle is to let the VAVBOX controller adjust the air volume at the end to meet the load requirements according to the indoor load changes, and transmit the air volume signal to the inverter controller. The inverter controller collects the air volume of each terminal within its jurisdiction, performs decoupling analysis and calculation, and then accumulates it to control the inverter and adjust the motor speed of the air conditioner so that the air supply volume is equal to the sum of the total terminal air volume.
 
The role of variable air volume control system
The variable air volume system means that the supply air changes with the exhaust air, and the exhaust air changes automatically or artificially according to people's needs. The supply air and the exhaust air form a dynamic balance, so that the room always maintains a relatively constant temperature and humidity. and slight negative pressure.
 
Its working principle is that when the exhaust air volume changes, the system end device automatically adjusts the air volume sent into the room to ensure that the indoor temperature, humidity and pressure are kept within the design range, so that the air supply volume of the air handling unit at low load decreases. , the speed of the blower of the air handling unit is also reduced to achieve the purpose of energy saving.

The VAV damper contains an averaging airflow measurement probe, airflow controller and actuator. Airflow is controlled based on actual flow measurement by changing the damper blade position. Flow control damper maintains the required airflow independent of duct pressure variation. Airflow control damper is available in several versions. The blade gasket enables airtight shut-off operation, and external insulation is used to attenuate radiated sound into the space.

 

company information
Automatically Adjustable Air Volume with Actuator Vav DamperAutomatically Adjustable Air Volume with Actuator Vav Damper

Shenzhen XICHENG EP LTD. is located in Baoan District, Shenzhen. It is an environmental protection equipment manufacturer which has been focusing on the environmental protection industry for many years and specializing in the production and sales of environmental protection equipment and various accessories. With the aims of "Quality First, Mutual Benefit, Cooperation and Win-Win", our company is directed by market demand and has independently developed new varieties to satisfy different industries needs for the differences and diversification of plastics.

Automatically Adjustable Air Volume with Actuator Vav Damper

FAQ

1. Q. Are you a trading company or manufacture?

     A: We are manufacture; we have our professional manufacturing teams and technicians

2. Q. How long is the warranty of your equipment?

     A:  One year warranty, in the meanwhile, quality inspection before delivery; during the warranty period, we

     can replace the damaged consumables for free, after the warranty period, we have a good price for

     consumables for our customers.

3. Q: Do you have technical support?

     A: Our Company is responsible for installation and debugging of equipment, meanwhile, responsible for the

     technology and operation training for user operator.

4.   Q:  Is overseas after-sales service available?

      A: Yes, and after installation we will teach you basic operation and maintenance method.

5.   Q:  May I customize my own equipment?

      A: Yes, please inform us your needs in details and we will design the facility per your data.

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now